| Load feeder fuseless, Reversing duty 400 V AC, Size S00 1.10...1.60 A 230 V AC screw terminal for installation on standard mounting rail (also fulfills type of coordination 1) Type of coordination 2, Iq = 150 kA 1 NC (contactor) |
Product brand name | SIRIUS |
Product designation | Reversing starter |
Design of the product | for standard rail or screw mounting |
Product type designation | 3RA22 |
Manufacturer's article number | |
of the supplied contactor | |
of the supplied circuit-breakers | |
of the supplied link module | |
General technical data |
Size of the circuit-breaker | S00 |
Size of load feeder | S00 |
Insulation voltage | |
with degree of pollution 3 at AC rated value | 690 V |
Surge voltage resistance rated value | 6 kV |
Protection class IP | |
on the front | IP20 |
of the terminal | IP20 |
Shock resistance | |
acc. to IEC 60068-2-27 | 6g / 11 ms |
Mechanical service life (switching cycles) | |
of contactor typical | 30 000 000 |
Type of assignment | 2 |
Type of protection according to ATEX directive 2014/34/EU | Ex II (2) GD |
Certificate of suitability according to ATEX directive 2014/34/EU | DMT 02 ATEX F 001 |
Ambient conditions |
Temperature compensation | -20 ... +60 °C |
Relative humidity during operation | 10 ... 95 % |
Main circuit |
Number of poles for main current circuit | 3 |
Design of the switching contact | electromechanical |
Adjustable pick-up value current of the current-dependent overload release | 1.1 ... 1.6 A |
Operating voltage | |
rated value | 690 V |
at AC-3 rated value maximum | 690 V |
Operating frequency rated value | 50 ... 60 Hz |
Operating current | |
at AC-3 | |
— at 400 V rated value | 1.5 A |
Operating power | |
at AC-3 | |
— at 400 V rated value | 550 W |
Control circuit/ Control |
Type of voltage of the control supply voltage | AC |
Control supply voltage at AC | |
at 50 Hz rated value | 230 V |
at 60 Hz rated value | 230 V |
Apparent holding power of magnet coil at AC | 4.2 V·A |
Auxiliary circuit |
Product extension Auxiliary switch | Yes |
Protective and monitoring functions |
Trip class | CLASS 10 |
Design of the overload release | thermal (bimetallic) |
UL/CSA ratings |
Full-load current (FLA) for three-phase AC motor | |
at 480 V rated value | 1.6 A |
Yielded mechanical performance [hp] | |
for three-phase AC motor | |
— at 460/480 V rated value | 0.75 hp |
— at 575/600 V rated value | 0.75 hp |
Short-circuit protection |
Product function Short circuit protection | Yes |
Design of the short-circuit trip | magnetic |
Conditional short-circuit current (Iq) | |
at 400 V acc. to IEC 60947-4-1 rated value | 150 000 A |
Installation/ mounting/ dimensions |
Mounting position | vertical |
Mounting type | screw and snap-on mounting onto 35 mm standard mounting rail |
Height | 170 mm |
Width | 90 mm |
Depth | 97 mm |
Required spacing | |
for grounded parts | |
— forwards | 32 mm |
— Backwards | 0 mm |
— upwards | 50 mm |
— at the side | 10 mm |
— downwards | 10 mm |
for live parts | |
— forwards | 32 mm |
— Backwards | 0 mm |
— upwards | 50 mm |
— downwards | 10 mm |
— at the side | 10 mm |
Connections/ Terminals |
Type of electrical connection | |
for main current circuit | screw-type terminals |
Safety related data |
B10 value | |
with high demand rate acc. to SN 31920 | 1 000 000 |
Proportion of dangerous failures | |
with high demand rate acc. to SN 31920 | 73 % |
Certificates/ approvals |