3RK1301-1EB00-0AA2
DS1-X FOR ET 200S

From SIEMENS

DS1-X for ET 200S Standard DOL starter expandable Setting range 2.8...4 A AC-3, 1.5 kW / 400 V Electromechanical starter for brake control module
Product brand nameSIMATIC
Product designationMotor starters
Design of the productdirect starter
Product type designationET 200S
General technical data
Product function
on-site operationYes
Power loss [W] typical10 W
Insulation voltage
rated value500 V
Degree of pollution3 at 400 V, 2 at 500 V according to IEC60664 (IEC61131)
Surge voltage resistance rated value6 kV
maximum permissible voltage for safe isolation
between main and auxiliary circuit400 V
Protection class IPIP20
Shock resistance5g / 11 ms
Operating frequency maximum750 1/h
Mechanical service life (switching cycles)
of the main contacts typical100 000
Type of assignment1
Reference code acc. to DIN 40719 extended according to IEC 204-2 acc. to IEC 750A
Reference code acc. to DIN EN 81346-2Q
Reference code acc. to DIN EN 61346-2Q
Product function
direct startYes
reverse startingNo
Product component Motor brake outputYes
Product feature
brake control with 230 V ACNo
brake control with 24 V DCNo
brake control with 180 V DCNo
brake control with 500 V DCNo
Product extension braking module for brake controlYes
Product function Short circuit protectionYes
Design of short-circuit protectioncircuit-breakers
Trip classCLASS 10
Maximum short-circuit current breaking capacity (Icu)
at 400 V rated value50 kA
Electromagnetic compatibility
EMC emitted interference
acc. to IEC 60947-1CISPR11, ambience A (industrial sector)
EMI immunity acc. to IEC 60947-1corresponds to degree of severity 3, ambience A (industrial sector)
Conducted interference
due to burst acc. to IEC 61000-4-42 kV on voltage supply, inputs and outputs
due to conductor-earth surge acc. to IEC 61000-4-52 kV (U > 24 V DC)
due to conductor-conductor surge acc. to IEC 61000-4-51 kV (U > 24 V DC)
Field-bound parasitic coupling acc. to IEC 61000-4-380 MHz ... 1 GHz 10 V/m, 1.4 GHz ...2 Hz 3 V/m, 2 GHz ... 2.7 GHz 1 V/m
Safety related data
B10 value
with high demand rate acc. to SN 319201 000 000
Proportion of dangerous failures
with low demand rate acc. to SN 3192050 %
with high demand rate acc. to SN 3192075 %
Failure rate [FIT]
with low demand rate acc. to SN 31920100 FIT
T1 value for proof test interval or service life acc. to IEC 6150820 y
Protection against electrical shockfinger-safe
Main circuit
Number of poles for main current circuit3
Design of the switching contactelectromechanical
Adjustable pick-up value current of the current-dependent overload release2.8 ... 4 A
Type of the motor protectionbimetal
Operating voltage
rated value200 ... 400 V
Operating frequency 1 rated value50 Hz
Operating frequency 2 rated value60 Hz
Relative positive tolerance of the operating frequency10 %
Relative negative tolerance of the operating frequency10 %
Operating range relative to the operating voltage at AC
at 50 Hz200 ... 440 V
Operating power
at AC-3
— at 400 V rated value1.5 kW
Inputs/ Outputs
Product function
digital inputs parameterizableNo
digital outputs parameterizableNo
Number of digital inputs0
Number of sockets
for digital output signals0
for digital input signals0
Supply voltage
Type of voltage of the supply voltageDC
Supply voltage 1 at DC24 ... 24 V
Supply voltage 1 at DC rated value
minimum permissible20.4 V
maximum permissible28.8 V
Control circuit/ Control
Type of voltage of the control supply voltageDC
Control supply voltage at DC
rated value20.4 ... 28.8 V
Control supply voltage 1
at DC rated value20.4 ... 28.8 V
at DC24 ... 24 V
Power loss [W] in auxiliary and control circuit
in switching state OFF
— with bypass circuit0.3744 W
— without bypass circuit0.374 W
in switching state ON
— with bypass circuit4.1184 W
— without bypass circuit4.118 W
Installation/ mounting/ dimensions
Mounting positionvertical, horizontal
Mounting typepluggable on terminal module
Height265 mm
Width45 mm
Depth120 mm
Ambient conditions
Installation altitude at height above sea level
maximum2 000 m
Ambient temperature
during operation0 ... 60 °C
during storage-40 ... +70 °C
during transport-40 ... +70 °C
Relative humidity during operation5 ... 95 %
Communication/ Protocol
Protocol is supported
PROFIBUS DP protocolYes
PROFINET protocolYes
Design of the interface
PROFINET protocolYes
Product function Bus communicationYes
Protocol is supported
AS-interface protocolNo
Product function
supports PROFIenergy measured valuesNo
supports PROFIenergy shutdownNo
address range memory of address range
of the inputs1 byte
of the outputs1 byte
Type of electrical connection
of the communication interfacevia backplane bus
for communication transmissionvia backplane bus
Connections/Terminals
Type of electrical connection
for main current circuitscrew-type terminals
Type of electrical connection
1 for digital input signalsusing control module
2 for digital input signalsusing control module
Type of electrical connection
at the manufacturer-specific device interfaceplug
for main energy infeedscrew-type terminals
for load-side outgoing feederScrew-type terminals
for main energy transmissionvia energy bus
for supply voltage line-sidevia backplane bus
for supply voltage transmissionvia backplane bus
UL/CSA ratings
Operating voltage
at AC at 60 Hz acc. to CSA and UL rated value600 V