3RV2011-0EA20-ZX95
CIRCUIT-BREAKER SPRING-L. CONN. 0.4A

From SIEMENS

Circuit breaker size S00 for motor protection, CLASS 10 A-release 0.28...0.4 A N-release 5.2 A Spring-type terminal Standard switching capacity Reusable packaging Pack = 40 units
Product brand nameSIRIUS
Product designationCircuit breaker
Design of the productFor motor protection
Product type designation3RV2
General technical data
Size of the circuit-breakerS00
Size of contactor can be combined company-specificS00, S0
Product extension
Auxiliary switchYes
Power loss [W] total typical5 W
Insulation voltage with degree of pollution 3 rated value690 V
Surge voltage resistance rated value6 kV
maximum permissible voltage for safe isolation
in networks with grounded star point between main and auxiliary circuit400 V
in networks with grounded star point between main and auxiliary circuit400 V
Protection class IP
on the frontIP20
of the terminalIP20
Shock resistance
acc. to IEC 60068-2-2725g / 11 ms
Mechanical service life (switching cycles)
of the main contacts typical100 000
of auxiliary contacts typical100 000
Electrical endurance (switching cycles)
typical100 000
Type of protectionIncreased safety
Certificate of suitability ATEXYes
Protection against electrical shockfinger-safe
Reference code acc. to DIN EN 81346-2Q
Ambient conditions
Installation altitude at height above sea level
maximum2 000 m
Ambient temperature
during operation-20 ... +60 °C
during storage-50 ... +80 °C
during transport-50 ... +80 °C
Temperature compensation-20 ... +60 °C
Relative humidity during operation10 ... 95 %
Main circuit
Number of poles for main current circuit3
Adjustable pick-up value current of the current-dependent overload release0.28 ... 0.4 A
Operating voltage
rated value690 V
at AC-3 rated value maximum690 V
Operating frequency rated value50 ... 60 Hz
Operating current rated value0.4 A
Operating current
at AC-3
— at 400 V rated value0.4 A
Operating power
at AC-3
— at 230 V rated value60 W
— at 400 V rated value90 W
— at 500 V rated value120 W
— at 690 V rated value180 W
Operating frequency
at AC-3 maximum15 1/h
Auxiliary circuit
Number of NC contacts for auxiliary contacts0
Number of NO contacts for auxiliary contacts0
Number of CO contacts
for auxiliary contacts0
Protective and monitoring functions
Product function
Ground fault detectionNo
Phase failure detectionYes
Trip classCLASS 10
Design of the overload releasethermal
Operational short-circuit current breaking capacity (Ics) at AC
at 240 V rated value100 kA
at 400 V rated value100 kA
at 500 V rated value100 kA
at 690 V rated value100 kA
Maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value100 kA
at AC at 400 V rated value100 kA
at AC at 500 V rated value100 kA
at AC at 690 V rated value100 kA
Breaking capacity short-circuit current (Icn)
at 1 current path at DC at 150 V rated value10 kA
with 2 current paths in series at DC at 300 V rated value10 kA
with 3 current paths in series at DC at 450 V rated value10 kA
Response value current
of instantaneous short-circuit trip unit5.2 A
UL/CSA ratings
Full-load current (FLA) for three-phase AC motor
at 480 V rated value0.4 A
at 600 V rated value0.4 A
Short-circuit protection
Product function Short circuit protectionYes
Design of the short-circuit tripmagnetic
Installation/ mounting/ dimensions
Mounting positionany
Mounting typescrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
Height106 mm
Width45 mm
Depth97 mm
Required spacing
with side-by-side mounting
— forwards0 mm
— Backwards0 mm
— upwards50 mm
— downwards50 mm
— at the side0 mm
for grounded parts
— forwards0 mm
— Backwards0 mm
— upwards50 mm
— at the side30 mm
— downwards50 mm
for live parts
— forwards0 mm
— Backwards0 mm
— upwards50 mm
— downwards50 mm
— at the side30 mm
Connections/Terminals
Product function
removable terminal for auxiliary and control circuitNo
Type of electrical connection
for main current circuitspring-loaded terminals
Arrangement of electrical connectors for main current circuitTop and bottom
Type of connectable conductor cross-sections
for main contacts
— single or multi-stranded2x (0,5 ... 4 mm²)
— finely stranded with core end processing2x (0.5 ... 2.5 mm²)
— finely stranded without core end processing2x (0.5 ... 2.5 mm²)
at AWG conductors for main contacts2x (20 ... 12)
Connectable conductor cross-section for main contacts finely stranded without core end processing0.5 ... 2.5 mm²
Design of screwdriver shaftDiameter 3 mm
Size of the screwdriver tip3,0 x 0,5 mm
Safety related data
B10 value
with high demand rate acc. to SN 319205 000
Proportion of dangerous failures
with low demand rate acc. to SN 3192050 %
with high demand rate acc. to SN 3192050 %
Failure rate [FIT]
with low demand rate acc. to SN 3192050 FIT
T1 value for proof test interval or service life acc. to IEC 6150810 y
Display version
for switching statusHandle